Customization: | Available |
---|---|
Media: | Air |
Temperature: | Ordinary Temperature |
Still deciding? Get samples of US$ 50/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Operation
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Approvals
Integrally piloted valves meet the requirements of:
1. C-Tick
2. EMC (89/336/CE)
3. ATEX II 3 G & D (94/9/CE) (when fitted with QR or QF type solenoids)
Pulse jet valve installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4, Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.
Product picture